Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Collector voltage of transistor (Vc) at "ON" signal from TCM | High level |
| Collector voltage of transistor (Vc) at "OFF" signal from ECM | Low level |
Time Needed for Diagnosis: 2.5 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.