Relay Box

  1. Install the relay box and connector bracket.

    Tightening torque: 

    13 N.m (1.3 kgf-m, 9.4 ft-lb) 

    Fig 1: Installing Relay Box And Connector Bracket
    G03808526Courtesy of SUBARU OF AMERICA, INC.
  2. Secure the relay box connector to connector bracket.
    CAUTION: Align the connector with mating receptacle.
  3. Connect the connector to relay box.
    Fig 2: Connecting Connector To Relay Box
    G03808527Courtesy of SUBARU OF AMERICA, INC.
  4. Install the air intake duct.
  5. Connect the battery ground cable to battery.