Abnormality Judgment
Judge NG when the continuous time of completing the malfunction criteria below becomes more than 2.5 seconds.
Judgment Value
JUDGMENT VALUE REFERENCE (ABNORMALITY)
| Malfunction Criteria | Threshold Value |
|---|---|
| Ignition switch | ON |
| Battery voltage | >10.9V |
| After engine starting | 1 second or more |
| Terminal output voltage when ECM sends OFF signal | Low |
Time Needed for Diagnosis: 2.5 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as the malfunction occurs.