Enable Condition: Notes
ENABLE CONDITION
| Secondary Parameters | Enable Conditions |
|---|---|
| Continuous time for completing all secondary parameters | > 1 second |
| Intake manifold pressure change during 0.5 engine rev. | < 16.0 kPa (120 mmHg, 4.72 inHg) (MT) |
| < 14.7 kPa (110 mmHg, 4.33 inHg) (AT) | |
| Engine speed change | < 1000 rpm/32 milliseconds |
| Throttle position change during 16 milliseconds seconds | < 14° |
| Fuel shut-off function | Not in operation |
| Atmospheric pressure | >/= 75.1 kPa(563 mmHg, 22.2 inHg) |
| Fuel level | >/= 9.6 lambda (2.54 US gal, 2.11 Imp gal) |
| VDC and AT control | Not in operation |
| Evaporative system check | Not in operation |
| Engine speed | 450 - 6700 RPM |
| Intake manifold pressure | > Map 3 or more |
| Battery voltage | >/= 8 V |