Diagnostic Method
Judge NG when the continuous time of completing the malfunction criteria becomes more than 5 seconds.
Judge OK and clear NG when the continuous time of incompleting the malfunction criteria becomes more than 5 seconds.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | -0.015 |
Time Needed for Diagnosis: 5 seconds x 1 times
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.