Diagnostic Method
Judge as NG when the malfunction criteria below are completed 3 time or more after the neutral SW change. And clear NG if there is change in the neutral SW.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Neutral switch signal (while changing from a to b below) | Low (OFF) continues |
Driving condition change
|
a) to b) |
Time Needed for Diagnosis: 3 monitoring
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.