Diagnostic Method: Notes
Judge as NG when the continuous time of meeting the all malfunction criteria below becomes more than the time needed for diagnosis (2 seconds).
Judgment Value
MALFUNCTION CRITERIA AND THRESHOLD VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Engine speed - Targeted engine speed | ≥ 1500 rpm |
| Feedback value for ISC | ≤ 0 |
| Change of engine speed for every engine 120°CA | ≥ -5 rpm |
Time Needed for Diagnosis: 2 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.