Enable Condition (Used Only For Malfunction Judgment)
ENABLE CONDITIONS
| Secondary Parameters | Enable Conditions |
|---|---|
| Closed loop control with the rear oxygen sensor | In operation |
| Target output voltage of the rear oxygen sensor | ≥ 0.6 V |
| Amount of intake air | ≥ 10 g/s (1.323 lb/m) |
| Engine coolant temperature | ≥ 75°C (167°F) |
| Misfire detection every 200 rotations | ≤ 7 times |
| Compensation factor for front oxygen (A/F) sensor with main feedback control | Not in limit value |
| Battery voltage with main feedback control | > 10.9 V |
| Deceleration fuel cut of 5 seconds or more | Experienced |