Injector Control (Injection Quantity Control)
CAUTION:
After carrying out the Operation Check Mode, perform the Clear Memory Mode <Ref. to
OPERATION , Clear Memory Mode. > and Inspection Mode <Ref. to
PROCEDURE , Inspection Mode. >.
- On the «System Operation Check Mode» display screen, select the {Injector Control}.
- On the «Injector Control» display screen, select the {Injection Quantity Control}.
- On the «Start the Engine» display screen, start the engine and select the [OK].
- On the «Injection Quantity Control» display screen, select [up triangle] or [down triangle] to change the setting value, and select the [OK].
It is possible to set by 1%, ranging from 0 to 20%.
- Selecting the [NO] completes the Injection Quantity Control. The display will then return to the «Injector Control» screen.