Enable Condition
ENABLE CONDITION
| Secondary Parameters | Enable Conditions |
|---|---|
| Abnormality judgment (1) | |
| Time of establishing all secondary parameter conditions | ≥ 3 seconds |
| Battery voltage | ≥ 10.9 V |
| Engine speed | ≥ 1300 rpm |
| Engine coolant temperature | ≥ 60°C (140°F) |
| Target advance angle | > 0°CA |
| Target timing advance change amount | < 1.07°CA |
| Abnormality judgment (2) | |
| Battery voltage | ≥ 10.9 V |
| Engine speed | ≥ 500 rpm |
| Engine coolant temperature | ≥ 60°C (140°F) |
| AVCS control | Not in operation |