Diagnostic Method
- Abnormality Judgment
Judge as NG when the continuous time of meeting the malfunction criteria below becomes 1 second or more.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Output voltage difference between Max. and Min. | < 20 mV (Equivalent to approximately 0.5°C (33°F) near 25°C) |
Time Needed for Diagnosis: 1 second
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG when the malfunction criteria below are met.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Output voltage difference between Max. and Min. | ≥ 20 mV |