Diagnostic Method
Abnormality Judgment
If the following conditions are met, judge as NG.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Maximum output voltage | < 550 mV |
| Minimum output voltage | > 150 mV |
Time Needed for Diagnosis: 200 seconds
Malfunction Indicator Light Illumination: illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
When the following conditions are established, judged as OK.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Maximum output voltage | ≥ 550 mV |
| Minimum output voltage | ≤ 150 mV |