Enable Condition: Notes
ENABLE CONDITION
| Secondary Parameters | Enable Conditions |
|---|---|
| All secondary parameters enable conditions | 1 second or more |
| Intake manifold pressure change during 0.5 engine revs. | < 13.3 kPa (100 mmHg, 3.94 inHg) |
| Throttle position change during 16 milliseconds | < 21° |
| Fuel shut-off function | Not in operation |
| Barometric pressure | ≥ 75.0 kPa (563 mmHg, 22.2 inHg) |
| Fuel level | ≥ 9.6 l (2.54 US gal, 2.11 Imp gal) |
| AT torque control | Not in operation |
| Evaporative system leak check | Not in operation |
| Engine speed | 460 - 6400 rpm |
| Intake manifold pressure | > Value from Map 3 |
| Battery voltage | ≥ 8V |