CAUTION: Never use a mega tester (designed for reading high voltage) or any other similar instrument for this test; otherwise, the diodes may be damaged.
  1. Checking positive diode

    Check for continuity between the diode lead and positive side heat sink. The positive diode is in good condition if resistance is 1 Q. or less only in the direction from the diode lead to heat sink.

    Fig 1: Checking Positive Diode
    G05668176Courtesy of SUBARU OF AMERICA, INC.
  2. Checking negative diode

    Check for continuity between the negative side heat sink and diode lead. The negative diode is in good condition if resistance is 1 Ω or less only in the direction from the heat sink to diode lead.

    Fig 2: Checking Negative Diode
    G05668177Courtesy of SUBARU OF AMERICA, INC.