Diagnostic Method
- Abnormality Judgement
At the main IC, check the sent signal at each timing which occurs immediately after the tumble generator valve output is set to OFF → ON, and judge overcurrent NG when the overcurrent NG signal is sent 96 ms x 10 time(s) in a row.
Judgement Value
JUDGEMENT VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Overcurrent NG signal input | Low |
Time Needed for Diagnosis: 96 ms x 10 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgement
Judge as OK and clear the NG when the OK signal is sent.
Judgement Value
JUDGEMENT VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Overcurrent NG signal input | High |
Time Needed for Diagnosis: Less than 1 second