Diagnostic Method
- Abnormality Judgement
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgement Value
MALFUNCTION THRESHOLD VALUE
| Malfunction criteria | Threshold value |
|---|---|
| Sensor 1 input voltage | ≤ 0.224 V |
Time Needed for Diagnosis: 24 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgement
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Judgement Value
MALFUNCTION THRESHOLD VALUE
| Malfunction criteria | Threshold value |
|---|---|
| Sensor 1 input voltage | > 0.224 V |
Time Needed for Diagnosis: 24 ms