Diagnostic Method
Abnormality Judgement
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgement Value
JUDGEMENT VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | ≥ 8V |
| Amount of camshaft sensor signal during 2 revs. | Not = 2 |
Time Needed for Diagnosis: Engine two revolutions x 4 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgement
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Judgement Value
JUDGEMENT VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Voltage | ≥ 8 V |
| Amount of camshaft sensor signal during 2 revs. | = 2 |
Time Needed for Diagnosis: Two engine revolutions