System Operation Check Mode: Operation: Notes
- Prepare the Subaru Select Monitor kit. Refer to PREPARATION TOOL , General Description.
- Prepare PC with Subaru Select Monitor installed.
- Connect the USB cable between SDI (Subaru Diagnosis Interface) and USB port on the personal computer (dedicated port for the Subaru Select Monitor).NOTE: The dedicated port for the Subaru Select Monitor means the USB port which was used to install the Subaru Select Monitor.
- Connect the diagnosis cable to SDI.
- Connect SDI to data link connector located in the lower portion of the instrument panel (on the driver's side).
CAUTION: Do not connect the scan tools except for Subaru Select Monitor and general scan tool.
- Start the PC.
- Turn the ignition switch to ON (engine OFF) and run the "PC application for Subaru Select Monitor".
- On the «Main Menu» display screen, select the {Each System Check}.
- On the «System Selection Menu» display screen, select the {Engine Control System}.
- Click the [OK] button after the information of engine type has been displayed.
- On the «Engine Diagnosis» display screen, select the {System Operation Check Mode}.
- The following items are displayed on the monitor.DISPLAY CHART
Display Actuator ON/OFF Operation Immobilizer System Fuel Pump Control Fixed Idle Ignition Timing Idle Speed Control Injector Control EGR Valve Control Injector Control