Diagnostic Method
- Abnormality Judgement
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgement Value
JUDGEMENT VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | ≥ 7.9 kPa (59.6 mmHg, 2.3 inHg) |
| Fuel temperature | < 35 °C (95 °F) |
| Barometric pressure | ≥ 75 kPa (563 mmHg, 22.2 inHg) |
Time Needed for Diagnosis: 15000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgement
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Judgement Value
JUDGEMENT VALUE REFERENCE
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | < 7.9 kPa (59.6 mmHg, 2.3 inHg) |
Time Needed for Diagnosis: Less than 1 second