Diagnostic Method
- Abnormality Judgment
Judge NG when the malfunction criteria below are completed determined times or more after the neutral SW change.
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Neutral switch signal (while changing from a to b below) | HIGH (OFF) continues. |
Driving condition change
|
From a) to b) |
Time Needed for Diagnosis: 3 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear NG when there is change in the neutral SW.
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Neutral switch signal (while changing from a to b below) | Changes to LOW (ON). |
Driving condition change
|
From a) to b) |
Time Needed for Diagnosis: Less than 1 second