Enable Condition
ENABLE CONDITION REFERENCE CHART
| Secondary Parameters | Enable Conditions |
|---|---|
| Time of establishing all secondary parameter conditions | ≥ 3000 ms |
| Battery voltage | ≥ 10.9 V |
| Engine speed | ≥ 1300 RPM |
| Engine coolant temperature | ≥ 60 °C (140°F) |
| AVCS control | Operation |
| Target timing advance change amount (per 64 ms) | < 1.07°CA |