Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Time of heater control duty at 70 % or more | ≥ 36000 ms |
| Front oxygen (A/F) sensor impedance. | > 500 Ω |
Time Needed for Diagnosis: 5000 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Front oxygen (A/F) sensor impedance. | ≤ 500 Ω |
Time Needed for Diagnosis: Less than 1 second