Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgment Value
JUDGMENT VALUE REFERENCE CHARTMalfunction Criteria Threshold Value Neutral switch signal in ECM when "P"/"N" range in TCM are "OFF" and when the other switches are "ON" LOW (ON) Time Needed for Diagnosis: 100 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
Judgment Value
JUDGMENT VALUE REFERENCE CHARTMalfunction Criteria Threshold Value Neutral switch signal in ECM when "P"/"N" range in TCM are "OFF" and when the other switches are "ON" HIGH (OFF) Time Needed for Diagnosis: Less than 1 second