LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2012 >> Forester X, Automatic Trans >> Repair and Diagnosis (Single Page) >> Engine Performance >> Testing & Diagnosis >> Diagnostic Trouble Code (DTC) Detecting Criteria (H4DO) >> Diagnostic Trouble Code (DTC) Detecting Criteria >> DTC P0139 O2 Sensor Circuit Slow Response (Bank 1 Sensor 2) >> Diagnostic Method
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Method

JUDGMENT VALUE REFERENCE CHART (INTERMEDIATE)

Malfunction Criteria Threshold Value
Shortest time change from rich (0.5 V O2 output) to lean (0.2 V) when voltage reduces from 0.55 V to 0.15 V > 491 ms
or
Longest time over 0.55 V
≥ 2000 ms
JUDGMENT VALUE REFERENCE CHART (WIDE)

Malfunction Criteria Threshold Value
Shortest time change from rich (0.6 V O2 output) to lean (0.1 V) when voltage reduces from 0.65 V to 0.05 V > Value from Map
or
Longest time over 0.65 V
≥ 2000 ms
ENABLE CONDITION REFERENCE CHART

Estimated temperature of rear oxygen sensor element when fuel cut starts °C (°F) 0 (32) 450 (842) 480 (896) 500 (932) 1000 (1832)
Longest time in rich status after fuel cut (ms) 2000 2000 2000 2000 2000

Time Needed for Diagnosis:  1 time(s)

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

JUDGMENT VALUE REFERENCE CHART (INTERMEDIATE)

Malfunction Criteria Threshold Value
Shortest time change from rich (0.5 V O2 output) to lean (0.2 V) when voltage reduces from 0.55 V to 0.15 V ≤ 491 ms
JUDGMENT VALUE REFERENCE CHART (WIDE)

Malfunction Criteria Threshold Value
Shortest time change from rich (0.6 V O2 output) to lean (0.1 V) when voltage reduces from 0.65 V to 0.05 V ≤ 2000 ms

Time Needed for Diagnosis:  1 time(s)



When the oxygen sensor output voltage changes from 0.25 V (lean) to 0.55 V (rich), calculate the minimum response time for output change between 0.3 V and 0.5 V for the judgment criteria.

Fig 1: Rear Oxygen Sensor Output Voltage Graph
G07669709Courtesy of SUBARU OF AMERICA, INC.
JUDGMENT VALUE REFERENCE CHART

Malfunction Criteria Threshold Value
Shortest time change from lean (0.3 V O2 output) to rich (0.5 V) when voltage changes from 0.25 V to 0.55 V > 4000 ms
or
Longest time under 0.25 V
≥ 120000 ms

Time Needed for Diagnosis:  1 time(s)

Malfunction Indicator Light Illumination:  Illuminates when malfunction occurs in 2 continuous driving cycles.

JUDGMENT VALUE REFERENCE CHART

Malfunction Criteria Threshold Value
Shortest time change from lean (0.3 V O2 output) to rich (0.5 V) when voltage changes from 0.25 V to 0.55 V ≤ 4000 ms

Time Needed for Diagnosis:  1 time(s)