Check Room Light Operation
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK ROOM LIGHT OPERATION. Make sure the room light illuminates when the room light switch is ON, and goes off when the switch is OFF. |
Does the room light illuminate or go off? | Go to step 2. | Check the room light circuit. Refer to LI-64, INSPECTION, Room Light. |
2 CHECK ROOM LIGHT OPERATION.
|
Does the room light illuminate ↔ go off (including off delay) when the door is opened and closed? | Go to step 3. | Go to step 4 . |
| 3 CHECK KEYLESS ENTRY OPERATION. Press the LOCK/UNLOCK button of the keyless transmitter. |
Does it operate properly? | Replace the body integrated unit. Refer to , BODY INTEGRATED UNIT . | Check the keyless entry control module. Refer to , SYMPTOM CHART , INSPECTION, Keyless Entry System. |
4 CHECK ROOM LIGHT.
|
Is room light normal? | Go to step 5. | Replace the bulb or room light assembly. |
5 CHECK HARNESS.
|
Is harness normal? | Go to step 6. | Repair or replace the harness. |
| 6 CHECK HARNESS. Measure the voltage between room light connector and chassis ground. Connector & terminal (R52) No. 3 (+) - Chassis ground (-): |
Is the voltage 10 V or more? | Replace the body integrated unit. Refer to , BODY INTEGRATED UNIT . | Repair or replace the harness. |