Diagnostic Method
Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | ≥ 8 V |
| Amount of camshaft sensor signal during 2 revs of crankshaft. | Not = 2 |
Time Needed for Diagnosis: Two engine revs. x 4 time(s)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Voltage | ≥ 8 V |
| Amount of camshaft sensor signal during 2 revs. | = 2 |
Time Needed for Diagnosis: Two engine revs.