Enable Condition
| Secondary Parameters | Enable Conditions |
|---|---|
| Time needed for all secondary parameters to be in enable conditions | ≥ 5000 ms |
| Vehicle speed | ≥ 2 km/h (1.2 MPH) |
| All conditions of EVAP canister purge | Completed |
| Learning value of evaporation gas concentration (left and right) | < 0.08 |
| Main feedback compensation coefficient (left and right) | ≥ 0.9 |
| Battery voltage | ≥ 10.9 V |