Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Neutral switch signal in ECM when "P"/"N" range in TCM are "OFF" and when the other switches are "ON" | LOW (ON) |
Time Needed for Diagnosis: 100 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Neutral switch signal in ECM when "P"/"N" range in TCM are "OFF" and when the other switches are "ON" | HIGH (OFF) |
Time Needed for Diagnosis: Less than 1 second