Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | ≥ 0.032 (PZEV model) ≥ 0.02 (except for PZEV model) |
Time Needed for Diagnosis: 5 s x 1 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | < 0.032 + 0 (PZEV model) < 0.02 + 0 (except for PZEV model) |
Time Needed for Diagnosis: 5 s