Diagnostic Method
Judge as OK and clear the NG when the malfunction criteria below are met.
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Motor power voltage | ≥ 5 V |
Time Needed for Diagnosis:
- 400 ms (NG judgment)
- 2000 ms (OK judgment)
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.