Unit inspection
- Fuel sender gauge assembly check (fuel sender gauge main)
- Visual inspection
- Check the fuel sender gauge assembly for damage.
- Check the dimensions between the float and fuel tank seating surface when the float is at F (upper limit) and E (lower limit).
DIMENSION
| Float position F (upper limit) - fuel tank seating surface |
121 to 129 mm {4.76 to 5.08 in} |
| Float position E (lower limit) - fuel tank seating surface |
14.7 to 22.7 mm {0.579 to 0.894 in} |
Courtesy of SUBARU OF AMERICA, INC.
- Resistance check
WARNING:
Be careful of fire.
- Check that the float moves smoothly between the positions F (upper limit) and E (lower limit).
- Check the resistance between the connector terminals when the float is at F (upper limit) and E (lower limit). Also check that the resistance varies continuously.
RESISTANCE
| Inspection terminals |
Inspection conditions |
Standard value |
| 1 - 2 |
Float position F (upper limit) |
6.5 to 8.5 Ω |
| Float position E (lower limit) |
168 to 172 Ω |
Courtesy of SUBARU OF AMERICA, INC.
- Fuel sender gauge assembly NO. 2 check (fuel sender gauge sub)
- Visual inspection
- Check the fuel sender gauge assembly NO. 2 for damage.
- Check the dimensions between the float and fuel tank seating surface when the float is at F (upper limit) and E (lower limit).
DIMENSION
| Float position F (upper limit) - fuel tank seating surface |
150.3 to 158.3 mm {5.92 to 6.23 in} |
| Float position E (lower limit) - fuel tank seating surface |
0.7 to 8.7 mm {0.03 to 0.34 in} |
Courtesy of SUBARU OF AMERICA, INC.
- Resistance check
WARNING:
Be careful of fire.
- Check that the float moves smoothly between the positions F (upper limit) and E (lower limit).
- Check the resistance between the connector terminals when the float is at F (upper limit) and E (lower limit). Also check that the resistance varies continuously.
RESISTANCE
| Inspection terminals |
Inspection conditions |
Standard value |
| 1 - 2 |
Float position F (upper limit) |
5.5 to 9.5 Ω |
| Float position E (lower limit) |
236 to 244 Ω |
Courtesy of SUBARU OF AMERICA, INC.