Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Front oxygen (A/F) sensor impedance | > 87 Ω |
Time Needed for Diagnosis: 10000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Front oxygen (A/F) sensor impedance | ≤ 87 Ω |
Time Needed for Diagnosis: 10000 ms