Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | < -0.042 (AT model except for PZEV) < -0.039 (MT model except for PZEV) < -0.035 (PZEV AT model) < -0.035 (PZEV MT model) |
Time Needed for Diagnosis: 1 s x 1 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | ≥ -0.042 + 0 (AT model except for PZEV) ≥ -0.039 + 0 (MT model except for PZEV) ≥ -0.035 + 0 (PZEV AT model) ≥ -0.035 + 0 (PZEV MT model) |
Time Needed for Diagnosis: 1 s