Diagnostic Method
- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Throttle sensor opening angle at full close point learning | < 9.975 ° |
| or | |
| > 20.025 ° | |
| or | |
| Throttle opening angle when the ignition switch is ON - Throttle minimum stop position | < 1.162 ° |
Time Needed for Diagnosis: 8 ms - 80 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Throttle sensor opening angle at full close point learning | ≥ 9.975 ° |
| and | |
| ≤ 20.025 ° | |
| Throttle opening angle when the ignition switch is ON - Throttle minimum stop position | ≥ 1.162 ° |
Time Needed for Diagnosis: 8 ms