Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Output voltage difference between Max. and Min. | < 0.02 V(Equivalent to approximately 0.5°C (0.9°F) near 25°C) |
Time Needed for Diagnosis: Less than 1 second
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established.