Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Σ |(ro2sadn - ro2sadn-1 )| / Σ |(sglmdn - sglmdn-1 )| | > 18 |
Time Needed for Diagnosis: 30 - 55 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment