Mode E (Measurement of reference pressure for judgment)
- Purpose: Judge the reference pressure stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC |Pressure sensor maximum output value - Pressure sensor minimum output value| > 0.3 kPa (2.355 mmHg, 0.1 inHg) P2404 - Purpose: Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions. Judge the vacuum pump performance stability.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC Reference pressure for judgment < Value of Map 5
or
> Value of Map 6P2404 MAP 5Atmospheric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -4.5 (-34.02, -1.3) -4.6 (-34.815, -1.4) -4.7 (-35.618, -1.4) -4.9 (-36.42, -1.4) MAP 6Atmospheric pressure kPa (mmHg, inHg) 70 (525, 20.7) 80 (600, 23.6) 90 (675, 26.6) 100 (750, 29.5) Reference pressure for judgment kPa (mmHg, inHg) -0.8 (-6.18, -0.2) -0.9 (-6.983, -0.3) -1 (-7.785, -0.3) -1.1 (-8.58, -0.3) - Purpose: Judge the presence of evaporative emission system leak.
Judge as NG when the following conditions are established.
JUDGMENT VALUEMalfunction Criteria Threshold Value DTC < Large leak (0.04 inch) > P0455 Leak pressure ≥ lleakjdg (Pa) lleakjdg = (Reference pressure for judgment) x 0.377 - (-45.5 Pa) < Very small leak (0.02 inch) > P0456 Leak pressure < lleakjdg (Pa)
Time Needed for Diagnosis: Approx. 23 min
- Abnormality Judgment
At next engine start, confirm whether the enable conditions are satisfied even though refueling has been done during soaking, and determine the malfunction.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
At next engine start, confirm whether the enable conditions are satisfied even though refueling has been done during soaking, then, if the following conditions are established, judge as OK and clear the NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| NG flag | Not set | P0455 P0456 P1451 P2404 |