Diagnostic Method: Notes
- When the conditions during which the differences of AVCS target timing advance amount and AVCS actual timing advance amount is large continues for certain amount of time.
- When the differences of target timing advance amount and actual timing advance amount is calculated during AVCS control, and the difference per predetermined time is the specified value or larger.
- Abnormality Judgment
Judge as NG when the following conditions are established within the predetermined time.