Diagnostic Method
When the conditions during which the differences of AVCS target timing advance amount and AVCS actual timing advance amount is large continues for certain amount of time.
- Abnormality Judgment
Judge as NG when the following conditions are established within the predetermined time.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| (Target position - Actual position) | > 10 °CA or < -10 °CA |
Time Needed for Diagnosis: 5000 ms
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established within the predetermined time.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| (Target position - Actual position) | ≤ 10 °CA and ≥ -10 °CA |
Time Needed for Diagnosis: 5000 ms