Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Voltage of the neutral position switch signal | ≤ Battery voltage X 0.19 V |
Time Needed for Diagnosis: 64 ms X 100 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.