Publication date: 2017-02-23
Reference number: 11-171-17

REPROGRAMMING FILE AVAILABILITY FOR SPARK KNOCK (PING)

REPROGRAMMING FILE AVAILABILITY FOR SPARK KNOCK (PING)

TECHNICAL SERVICE BULLETIN

Reference Number(s): 11-171-17, Date of Issue:  February 23, 2017
SUBARU: 2015-2017 WRX

APPLICABILITY

2015-2017MY WRX 2.0L Models

INTRODUCTION

This bulletin announces the availability of reprogramming files to optimize the ECM and address isolated customer concerns of a spark knock (engine ping) -type sound.

PRODUCTION CHANGE INFORMATION

The new logic was incorporated into production starting with VIN: H*828389. 

PACK FILE APPLICABILITY

NOTE: These new files will be included in the January, 2017 SSM Update.
Model Transmission Type PAK File Name New ECM Part Number Old ECM Part Numbers Decryption Keyword New CID Number
2015MY WRX 2.0L 6MT 22765AG237.pak 22765AG237 22765AG230, 231, 232, 233, 234, 235 and 236 B12584AB LF75401S
CVT 22765AG247.pak 22765AG247 22765AG240, 241, 242, 243, 244, 245 and 246 F8AF048A LF75401T
2016MY WRX 2.0L 6MT 22765AH612.pak 22765AH612 22765AH610, 611 600B66B7 LF75401H
CVT 22765AH622.pak 22765AH622 22765AH620, 621 FA69DC40 LF75401G
2017MY WRX 2.0L 6MT 22765AK381.pak 22765AK381 22765AK380 7D45CC9B LF79100P
CVT 22765AK391.pak 22765AK391 22765AK390 8ED7E0BF LF79100N

SERVICE PROCEDURE

Subaru of America, Inc. (SOA) highly recommends connecting the Subaru Midtronics GR8 Diagnostic Battery Charger to the vehicle and utilizing the Power Supply Mode feature anytime a vehicle control module is being reprogrammed. Follow the procedure as outlined in document GR8-1100 on STIS for use of the GR8's Power Supply Mode:

IMPORTANT: This information is applicable to the Midtronics GR8 Diagnostic Battery Charger ONLY  . It does not apply to any other brand/type of "generic" battery charger whatsoever. ONLY the GR8 and its Power Supply Mode feature has been tested and approved by SOA.

Once the GR8 is connected to the vehicle, as long as the battery is fully charged  , it takes less than 3 minutes to boot-up the charger, select Power Supply Mode, and have the battery voltage stabilized and ready for reprogramming.

REMINDER:  If the GR8 indicates the vehicle's battery must be charged, charge the battery using the GR8 before proceeding to reprogram the vehicle.

NOTE: Control module failures as a result of battery discharge during reprogramming are not a matter for warranty. Should any DTCs reset after the reprogramming update is performed, diagnose per the procedure outlined in the applicable Service Manual.

WARRANTY/CLAIM INFORMATION

For vehicles within the Basic New Car Limited, an applicable Emission Warranty period or covered by an active Subaru Added Security Classic or Gold plan, this repair may be submitted using the following claim information:

Labor Description Labor Operation # Fail Code Labor Time
MFI OBDII ECM Reprogramming A455-288 UPG-48 0.4
IMPORTANT: Always  note the original Calibration Identification number (CID) the vehicle came in with on the repair order before reprogramming and, make sure to list the NEW  CID for any newly-installed programming (as confirmed from the actual control module AFTER  installation). The NEW  CID MUST  also be noted on the repair order as this information is required for entry in the Miscellaneous Detail field during claim submission.
NOTE: The pack file listings provided in this bulletin are the latest available at the time of publishing. Updates are often released thereafter without revision to the original bulletin. For this reason, it is critical to always have the latest version of Select Monitor software installed on your system. You can confirm if a later version is available by entering the CID listed in this bulletin into FlashWrite. If a newer CID is shown as available in FlashWrite, reprogram using that file.