Inspection steps
- Reading values with SSM3 (answer-back operation)
- Connect the SSM3 to the DLC3.
- Turn IG SW to ON.
- Turn on the SSM3.
- Enter the following menus. [Integ. unit mode]→[Unit customizing]
- Referring to the TABLE below, perform settings.CONTROLLER ECM DISPLAY REFERENCE
Display Initial setting Contents Setting Controller ECM [Hazard Answer Back] ON When a door is locked by wireless operation, the hazard warning lights flash once. When a door is unlocked by wireless operation, the hazard warning lights flash twice. OFF or ON Main body ECM (multiplex network body ECM) [Wireless Buzzer Resp] ON Wireless door lock buzzer response OFF or ON Main body ECM (multiplex network body ECM) [Wireless Buzzer Volume] Level 5 Wireless door lock buzzer volume Level 7, Level 6, Level 5, Level 4, Level 3, Level 2, Level 1, or Level 0 Main body ECM (multiplex network body ECM) Result
Result Go to Both items are ON and levels except 0 A Both items are OFF or level 0 B B: Execute the customize function.
A: Go to next step
- Inspecting wireless door lock control function
- Inspect the wireless door lock control functions using the door control transmitter module set sub-assembly.
Result
Result Go to The wireless door lock/unlock functions operate properly. A The wireless door lock/unlock functions do not operate properly. B B: Go to "SYMPTOM TABLE " (Refer to ).
A: Go to next step
- Inspect the wireless door lock control functions using the door control transmitter module set sub-assembly.
- Checking wireless answer-back operation
- Inspect the wireless answer-back operation using the door control transmitter module set sub-assembly.
Result
Result Go to Only wireless door lock buzzer answer-back does not occur. A Only hazard warning light answer-back does not occur. B B: Go to Step 8.
A: Go to next step
- Inspect the wireless answer-back operation using the door control transmitter module set sub-assembly.
- Executing system operation check mode with SSM3 (wireless door lock buzzer)
- Connect the SSM3 to the DLC3.
- Turn IG SW to ON.
- Turn on the SSM3.
- Enter the following menus. [Integ. unit mode] →[Work Support]→[System Operation Check Mode]
- Execute the system operation check mode according to the SSM3 display.
Main body
MAIN BODY TESTER DISPLAY REFERENCETester display Tested parts Control range Notes for diagnosis [Keyless Buzzer Output] Wireless door lock buzzer ON/OFF - Result
Result Go to Wireless door lock buzzer do not turn ON/OFF. A Wireless door lock buzzer turns ON/OFF. B B: Replacement of the main body ECM (multiplex network body ECM)
A: Go to next step
- Inspecting wiring harness and connector (wireless door lock buzzer - main body ECM)
- Disconnect the wireless door lock buzzer connector A63.
- Disconnect the connector A73 of the main body ECM (multiplex network body ECM).
- Measure the resistance according to the following table.
Resistance
RESISTANCE REFERENCEInspection terminals Inspection conditions Standard value A63-1 - A73-1 Always 1 Ωor less A63-2 - Chassis ground Always 1 Ωor less A63-1 - Chassis ground Always 10 kΩ or more NG: Repair or replacement of wiring harness or connector
OK: Go to next step
- Replacing wireless door lock buzzer
- Temporarily replace the wireless door lock buzzer with a new one. (Refer to REMOVAL
)
Next
- Temporarily replace the wireless door lock buzzer with a new one. (Refer to REMOVAL
)
- Checking wireless door lock buzzer operation
- Check the wireless answer-back function operation.
Criteria: The wireless answer-back function operates properly
NG: Replacement of the main body ECM (multiplex network body ECM)
OK: Complete (Wireless door lock buzzer is faulty)
- Check the wireless answer-back function operation.
- Hazard warning light operation
- Check that the hazard warning light blinks when the hazard warning switch is pressed.
Criteria: Hazard warning light signal is normal
NG: Refer to the lighting system (Symptom table)
OK: Replacement of the main body ECM (multiplex network body ECM)
- Check that the hazard warning light blinks when the hazard warning switch is pressed.