Diagnostic Method
Judge as NG when one of the following conditions is established.
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| (1) Main throttle opening angle - Main throttle opening angle at monitoring start | ≥ 2 ° |
| (2) Monitoring IC motor continuity cut demand | None |
| (3) Monitoring IC register writing value | Reading value |
Time Needed for Diagnosis:
- 24 ms
- 2984 ms = (25 + 6) X 0.008 + (4 X 25 + 4) X 0.008 + (5 X 25 + 9) X 0.008 + (2 X 25) X 0.008 + (25 + 2) X 0.008 X 2
- 200 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.