Home >> Subaru >> 2017 >> BRZ Limited, Automatic Trans >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transaxle (Diagnostics) >> Automatic transmission system >> DTC P2719, P2720, P2721: Pressure Control Solenoid "D" Control Circuit Range/Performance, Pressure Control Solenoid "D" Control Circuit Low, Pressure Control Solenoid "D" Control Circuit High >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P2719, P2720, P2721: Pressure Control Solenoid "D" Control Circuit Range/Performance, Pressure Control Solenoid "D" Control Circuit Low, Pressure Control Solenoid "D" Control Circuit High: Notes

Circuit description

The line pressure control solenoid ASSY (SLT) is controlled according to the duty signal which is predetermined by the transmission control computer ASSY based on signals from the accelerator position sensor and the transmission revolution sensor (SP2, NT). This adjusts line pressure to meet the throttle opening angle and engine output. The transmission control computer ASSY detects slippage of clutch, etc. based on the revolution speed of the transmission revolution sensor (SP2, NT).

DTC No. SAE/TCCS DTC detecting condition
  1. Diagnosis condition
  2. Abnormal status
  3. Abnormal period
  4. Others
Inspection parts
P2719
  1. Learning control is not prohibited.
  2. The cumulative difference between line pressure control solenoid ASSY (SLT) operation set current and operation feedback current is 12 A or more.
  3. Abnormal status of No. 2 is detected 2 times consecutively.
  4. trips
  • Line pressure control solenoid ASSY (SLT)
  • Transmission wire
  • Wiring harness or connector
  • Transmission control computer ASSY
P2720
  • Learning control is not prohibited.
  • Operation feedback voltage is less than 0.018 V after line pressure control solenoid ASSY is turned OFF and 1 second or more has passed.
  • 100 ms or more durations are detected 5 times consecutively.
  • trips
  • Wiring harness and connector
  • Transmission wire
  • Line pressure control solenoid ASSY (SLT)
  • Transmission control computer ASSY
P2721
  1. Learning control is not prohibited.
  2. Operation feedback voltage is more than 0.257 V after line pressure control solenoid ASSY is turned ON and 1 second or more has passed.
  3. 100 ms or more durations are detected 5 times consecutively.
  4. trips
  • Wiring harness and connector
  • Transmission wire
  • Line pressure control solenoid ASSY (SLT)
  • Transmission control computer ASSY

Monitor description

If open or short circuit is detected in the circuit, TCM recognizes it as a malfunction.

TCM turns on MIL and records the diagnostic codes.

MONITOR STRATEGY DESCRIPTION

Applicable diagnostic codes P2719: Pressure Control Solenoid "D" Control Circuit Range/Performance
P2720: Pressure Control Solenoid "D" Control Circuit Low
P2721: Pressure Control Solenoid "D" Control Circuit High
Required sensor/component Line pressure control solenoid ASSY (SLT)
Operation frequency Consecutive
Period P2719: 2 count
P2720: 0.1 seconds x 5 times
P2721: 0.1 seconds x 5 times
MIL operation Immediate
Operation order None

TYPICAL ENABLING CONDITIONS

TYPICAL ENABLING CONDITIONS DESCRIPTION

Battery voltage 10.2 V or more
Above condition is established 2 seconds or more
Fail safe mode (solenoid power supply shut down) Non-active
Line pressure control solenoid ASSY (SLT) (P2720, P2721) No defect
Check the feedback terminal voltage. 0.257V or less
Battery voltage 10.5V or more
Above condition (battery voltage) is established 0.5 seconds or more
TYPICAL ENABLING CONDITIONS DESCRIPTION

Battery voltage 10.2 V or more
Above condition is established 2 seconds or more
Fail safe mode (solenoid power supply shut down) Non-active
Line pressure control solenoid ASSY (SLT) (P2719) No defect
TYPICAL ENABLING CONDITIONS DESCRIPTION

Battery voltage 10.2 V or more
Above condition is established 2 seconds or more
Fail safe mode (solenoid power supply shut down) Non-active
Line pressure control solenoid ASSY (SLT) (P2719) No defect

TYPICAL MALFUNCTION THRESHOLDS

TYPICAL MALFUNCTION THRESHOLDS DESCRIPTION

Cumulative total of differences between target current and feedback current (Sum_ie) 12 A or more
Sum_ie is updated every 25 milliseconds.
When 1 or more conditions below are established, Sum_ie is deleted.
  1. The permission condition is not established.
  2. When the current difference (ie) between target and feedback is -50 mA to 50 mA
  3. Positive and negative of ie are reversed.
TYPICAL MALFUNCTION THRESHOLDS DESCRIPTION

Check the feedback terminal voltage. 0.018 V or less
Time elapsed after recovery from battery short circuit 1 second or more
TYPICAL MALFUNCTION THRESHOLDS DESCRIPTION

Check the feedback terminal voltage. 0.257V or more
Time elapsed after recovery from short circuit to ground/open circuit 1 second or more