Execution Condition
EXECUTION CONDITION
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Barometric pressure | > 75.1 kPa (563 mmHg, 22.2 inHg) |
| Duration of main feedback | ≥ 3000 ms |
| Engine speed | ≥ 1000 rpm |
| Amount of intake air | ≥ 10 g/s (0.35 oz/s) (CVT model) |
| ≥ 10 g/s (0.35 oz/s) (MT model) |
EXECUTION CONDITION
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Barometric pressure | ≥ 75.1 kPa (563 mmHg, 22.2 inHg) |
| Main feedback | In operation |
| Vehicle speed | > 40 km/h (24.9 MPH) |
| Engine speed | ≥ 1000 rpm |
| and < 4000 rpm | |
| Amount of intake air | ≥ 7.5 g/s (0.26 oz/s) |
| and < 40 g/s (1.41 oz/s) | |
| Catalyst depletion diagnosis | Not under diagnosis |