Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Absolute value (Evaporative Leak Check Module pressure sensor output value - intake manifold pressure (absolute pressure) when ignition switch is ON) |
> 4.7 kPa (35.5 mmHg, 1.4 inHg) |
Time needed for diagnosis: 320 ms
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.