Execution Condition
| Secondary Parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Sub feedback | In operation |
| Amount of intake air | ≥ 8 g/s (0.28 oz/s) |
| Estimated temperature of the rear oxygen sensor element | ≥ 500 °C (932 °F) (CVT model) ≥ 500 °C (932 °F) (MT model) |
| Enable conditions at interrupt control are as follows | |
| Continuous time when rear oxygen sensor output voltage is less than 0.55 V | ≥ 5 s (CVT model) ≥ 15 s (MT model) |
| Air fuel ratio reduced from target air fuel ratio | = Value of Map |
MAP (CVT MODEL) VALUE SPECIFICATION
| Output voltage of rear oxygen sensor V |
0.000 | 0.150 | 0.200 | 0.400 | 0.600 |
| Air fuel ratio reduced from target air fuel ratio % |
15 | 15 | 4 | 4 | 4 |
MAP (MT MODEL) VALUE SPECIFICATION
| Output voltage of rear oxygen sensor V |
0.000 | 0.150 | 0.200 | 0.400 | 0.600 |
| Air fuel ratio reduced from target air fuel ratio % | 15 | 15 | 4 | 4 | 4 |