| P0071 |
AMBIENT AIR TEMPERATURE SENSOR CIRCUIT "A" RANGE/PERFORMANCE |
- 6 hours have elapsed since ignition switch is OFF under a completely warmed up condition.
- For models with block heater, at least 6 hours must have elapsed without operating the block heater.
|
2 |
| P0116 |
ENGINE COOLANT TEMPERATURE SENSOR 1 CIRCUIT RANGE/PERFORMANCE |
- 6 hours have elapsed since ignition switch is OFF under a completely warmed up condition.
- For models with block heater, at least 6 hours must have elapsed without operating the block heater.
|
2 |
| P0196 |
ENGINE OIL TEMPERATURE SENSOR "A" RANGE/PERFORMANCE |
- 6 hours have elapsed since ignition switch is OFF under a completely warmed up condition.
- For models with block heater, at least 6 hours must have elapsed without operating the block heater.
|
2 |
| P0451 |
EVAP SYSTEM (CPC) PRESSURE SENSOR/SWITCH CIRCUIT RANGE/PERFORMANCE |
60 seconds have elapsed since ignition switch is OFF. |
2 |
| P050A |
COLD START IDLE CONTROL SYSTEM PERFORMANCE |
- |
2 |
| P050B |
COLD START IGNITION TIMING PERFORMANCE |
- |
2 |