Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut has completed | ≤ 0.15 V |
| ((Fuel system status | = Fuel cut |
| for time) | ≥ 5000 ms |
| followed by fuel system status) | Fuel cut |
| Estimated element temperature of rear oxygen sensor when fuel cut has completed | ≥ 500 °C (932 °F) |
| Amount of intake air (Except for PZEV model) | ≥ 10 g/s (0.35 oz/s) |
| Amount of intake air (PZEV model) | ≥ 13 g/s (0.46 oz/s) |