Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Sub feedback | In operation |
| Amount of intake air | ≥ 10 g/s (0.35 oz/s) |
| Estimated temperature of the rear oxygen sensor element | ≥ 500 °C (932 °F) |
| Enable conditions at interrupt control are as follows Continuous time when rear oxygen sensor output voltage is less than 0.55 V |
≥ 5 s |
| Air fuel ratio reduced from target air fuel ratio | = Value of Map |
Map
| Output voltage of rear oxygen sensor V | 0.0 | 0.15 | 0.2 | 0.4 | 0.6 |
| Air fuel ratio reduced from target air fuel ratio % | 15 | 15 | 4 | 4 | 4 |